Ul u373. 3 2 hr. UL U429 2 1/2" (63.5 mm), 4" (102 mm) or ...

Albany, Georgia is the location marking GP’s third

It combines data from many legacy UL solutions, including the Online Certification Directory, Product Spec and several iQ databases into one streamlined experience. A free Product iQ account helps users verify UL certification of products and components, locate UL Solutions guide information and search for alternative certified products.Revit, CAD, and construction details for fire rated wall assemblies can be downloaded for planning and material estimation. About Our Sustainability Commitment Blog Careers Contact Us Where to Buy. Tools & Documents Data Sheets Safety Data Sheets FAQs Technical Support. Connect with us. Tel: 317-398-4434 Fax: 317-398-3675 Sales: 800-825-4434 ... UL Design U373 Area Separation Wall assembly was evaluated at a height up to 44’ (13,411 mm) and the ITS/WHI GP/WA 120-04 Area Separation Wall assembly was evaluated at a height up to 68’ (20,726 mm). To view installation video, visit http://www.gpgypsum.com (DensGlass Shaftliner). Erecting the 2” (51 mm) Area Separation Wall 1. UL has conducted hundreds of analytical studies to understand individual aspects of home fires over the years. In 2012 UL brought its cumulative insights together in a series of unique tests to advance the science of residential fires. In order to understand the full implications of modern home fires, UL scientists conducted a series of3 2 hr. UL U429 2 1/2" (63.5 mm), 4" (102 mm) or 6" (152 mm) C-T Studs 40 Based on GA WP 7084 or C-H Studs 24" o.c. (610 mm), 1" (25.4 mm), 6" NGC 2618 Fire-Shield Shaftliner or 1" Fire-Shield Shaftliner XP and 1 layer of 1/2" (12.7 mm) Fire-Shield C Wallboard applied vertically on each side. Joints staggered 24" on opposite sides.Fire Test Reference: UL U373, ULC W312, WHI GP/WA 120-03, cUL U373. Sound Test Reference: RAL TL10-290. Area Separation Wall. Two layers 1” (25.4 mm) ToughRock Shaftliner or DensGlass® Shaftliner inserted in H-Studs 24” (610 mm) o.c. Min. 3/4” (19 mm) air space between liner panels and adjacent wood or metal framing. Sound Tested with 2 ...The present study investigated the effect of cystathionine on astrocytoma (U373) cell proliferation, the activity of γ-cystathionase (CTH) and changes in thiols ...the UL Fire Resistance Directory under UL Design U373 or U375, the ULC Fire Resistance Directory ULC Design No. W312 and the Warnock Hersey Listed Product and Code Compliance Directory under WHI GP/WA 120-04. Consult the applicable fire resistance directory for additional information. 2” (51 mm) x 4” (102 mm) Wood Framing Fiberglass Insulation. The smart choice to make spaces more comfortable and energy efficient. R-Value. The ability to resist heat flow — insulation's thermal resistance. Thermal Properties. Ability to provide thermal resistance for comfort and efficiency. Insulating for Sound. Sound absorption characteristics, helping reduce noise transmission.U251, 251MG, U 251, U 251 MG, U 251MG, 251MG, U-373 MG, U373, MG, U373MG Human glioblastoma astrocytoma Derived from a malignant glioblastoma tumour by explant technique. U-251 was formerly distributed as U-373 MG (ECACC catalogue number 89081403) until short tandem repeat (STR)-PCR profiling confirmed identity with U-251. …Architext Inc., providing font and bar code solutions for multiple platforms, including Windows, Macintosh, DOS, and UNIX. We also support multiple printers - HP ...Dec 5, 2019 · They want to use U373 for the rated wall. It is a 2 hr rated wall assembly for load bearing. They want to use configuration B which is shown in section as: 1/2" drywall. 2x4 studs at 24" o.c. 3/4" air space. (2) 1" drywall liners using friction fitted H shaped studs. 3/4" air space. 2x4 studs at 24" o.c. BXUV.U347 - Fire-resistance Ratings - ANSI/UL 263 Author: jnye Created Date: 3/13/2017 4:07:02 PM ...Jul 29, 2020 · Standard UL 263 shall be permitted to be used to determine the hourly fire endurance rating of walls and floors with control joints. 1.11 Tests for determining the surface burning characteristics of building materials, based on the rate of flame spread, are found in the Standard for Test for Surface Burning Characteristics of Building Materials ... Supporting the world with research and science. UL Research Institutes is a leading independent safety science organization with global reach. We sense and act on risks to public safety with bold hypotheses and objective investigations.Environmental Exposures (ANSI/UL 263, ASTM E119) 3. REFERENCED DOCUMENTS ANSI/UL 263, 14th Ed. (ASTM E119), Fire Tests of Building Construction and Materials ANSI/UL 723, 10th Ed. (ASTM E84), Test for Surface Burning Characteristics of Building Materials Fire Test Reference: UL U373, ULC W312, WHI GP/WA 120-03, cUL U373. Sound Test Reference: RAL TL10-290. Area Separation Wall. Two layers 1” (25.4 mm) ToughRock Shaftliner or DensGlass® Shaftliner inserted in H-Studs 24” (610 mm) o.c. Min. 3/4” (19 mm) air space between liner panels and adjacent wood or metal framing. Sound Tested with 2 ...Gypsum Board* — Any 5/8 in. thick UL Classified Gypsum Board that is eligible for use in Design Nos. L501, G512 or U305. Nom 5/8 in. thick 4 ft wide. Gypsum board applied horizontally or vertically, unless specified below, and nailed to studs and bearing plates 7 in. OC with 6d cement coated nails, 1-7/8 in. long, 0.0915 in. shank diam …AIA FloridaBailey Metal Products | Steel Building Materials ManufacturerUL is committed to meeting our customers’ needs. Understanding who is accessing UL certification data and how the data is being used is critical to being able to understand customer needs and interests. Account logins will also enable UL to provide relevant information and communications to each of our customers based on their preferences.Weird arrangement having exposed steel studs on one side, but UL assemblies will note "Exposure Side" and "Non-exposure Side" when the assembly is rated for exposure from one side, so this one appears to be rated from both sides. V. vegeta82 Member. Joined Apr 9, 2015 Messages 21 Location United States.Note has been added to Detail 1-Common Wall & Detail 6-Common wall on sheet AD-7, referencing UL U373 & UL U336 non-bearing 2-HR area separation items 1,2,3. Depicted below is from manufacturer’s fire rated product installation requirements as approved by ANSI/UL 263. Detail 1-Common Wall & Detail 6-Common Wall follow the …2/1/2019 FIRE-RESISTANCE RATINGS - ANSI/UL 263 | UL Product iQ https://iq.ulprospector.com/en/profile?e=14938 5/5 * Indicat es such pr oducts shall bear the UL or cUL Cer tification Mark for jur isdictions employing the UL or cUL Cer tification (such as Canada), respectively. Last Updated on 2018-03-05We would like to show you a description here but the site won’t allow us.UL Type Designations · Frequently Asked Questions · Acoustical Ceilings Performance Substrate · Sealant Fire Tests · Plasters - Committed To The Craft ...Wood and/or metal studs specified in UL Rated Designs are minimum sizes. Larger dimensional studs can be substituted.zOnly products which bear UL's Mark are considered as Classified, Listed, or Recognized. Fire Resistance Ratings - ANSI/UL 263 See General Information for Fire Resistance Ratings - ANSI/UL 263 Design No. U497 July 01, 2010 Nonbearing Wall Rating — 2 Hr BXUV.U497 Fire Resistance Ratings - ANSI/UL 263 Page BottomSound Tested with 2”x 4” stud wall with 1/2” (12.7 mm) ToughRock® Fireguard C wallboard or DensArmor Plus® Fireguard C panels and 3-1/2” (89 mm) fiberglass insulation in stud space. Breakaway clip facings and height of wall differ between UL Design U373 and WHI GP/WA 120-03. Consult each listing for specific information. The present study investigated the effect of cystathionine on astrocytoma (U373) cell proliferation, the activity of γ-cystathionase (CTH) and changes in thiols ...UL Type Designations; Material Estimators Material Estimators. Sheetrock® Wallboard Estimator; Ceilings Materials Estimator; Ensemble® Acoustical Drywall Ceiling Estimator; Vault Estimator; Dome Estimator; Vaulted Dome Estimator; Design Studio Design Studio. Wall Assemblies; Floor-Ceilings Assemblies;Fire Rating. 2 hours. System STC. 54-58. System Thickness. 6.75 in. CAD/Revit & Acoustics. Revit PDF. Visit UL U336 on the UL website. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow­Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The GuideArchitext Inc., providing font and bar code solutions for multiple platforms, including Windows, Macintosh, DOS, and UNIX. We also support multiple printers - HP ... Gypsum Board* — (As an alternate to Item 2) — Any 5/8 in. thick UL Classified Gypsum Board that is eligible for use in Design Nos. L501, G512 or U305 — Nom. 5/8 in. thick gypsum board, paper or vinyl faced with beveled, square, tapered or rounded edges. Gypsum board nailed toWe would like to show you a description here but the site won’t allow us.Fiberglass Insulation. The smart choice to make spaces more comfortable and energy efficient. R-Value. The ability to resist heat flow — insulation's thermal resistance. Thermal Properties. Ability to provide thermal resistance for comfort and efficiency. Insulating for Sound. Sound absorption characteristics, helping reduce noise transmission.Sep 19, 2023 · Supporting the world with research and science. UL Research Institutes is a leading independent safety science organization with global reach. We sense and act on risks to public safety with bold hypotheses and objective investigations. , Underwriters Laboratories (UL) Fire Resistance Directory, Intertek Testing Se rvices' Di-rectory of Listed Products, and the Gypsum Associa-tion's . Fire Resistance Design Manual (GA 600). The American Wood Council (AWC) and its members have tested a number of woodframe fire- -resistance-rated as-semblies (see photos). Descriptions of ...German submarine U-373 was a Type VIIC U-boat of Nazi Germany's Kriegsmarine during World War II. History. Nazi Germany. Name, U-373.Gypsum Board* — Any 5/8 in. thick UL Classified Gypsum Board that is eligible for use in Design Nos. L501, G512 or U305. Nom 5/8 in. thick 4 ft wide. Gypsum board applied horizontally or vertically, unless specified below, and nailed to studs and bearing plates 7 in. OC with 6d cement coated nails, 1-7/8 in. long, 0.0915 in. shank diam …Title: UL Design No. U366 Author: Powers Created Date: 3/26/2007 3:11:58 PMUL 263. August 5, 2021. Fire Tests of Building Construction and Materials. 1 Scope 1.1 These fire tests are applicable to assemblies of masonry units and to composite assemblies of structural materials for buildings, including bearing and other walls and partitions,... UL 263. September 9, 2020.• UL Listed E115376 (Ordinary Location) • IECEx and ATEX component certificate – BVS13ATEXE015U and IECEx BVS 13.0025U • 2G Ex eb IIC Gb or 2D Ex tb IIIC Db • TR-CU and EAC certified S-TB-T terminal boxes: S-TB enclosures are available assembled as custom configured and certified terminal boxes. Options include custom entries,Only products which bear UL's Mark are considered Certified. BXUV - Fire Resistance Ratings - ANSI/UL 263 Cer tified for United States BXUV7 - Fire Resistance Ratings - CAN/ULC-S101 Cer tified for Canada See General Information for Fire-resistance Ratings - ANSI/UL 263 Certified for United S tates Design Criteria and Allowable Variances• UL U370 • GA WP 3820 Figure 3. Options for fire resistance rated, wood frame wall assemblies that could be useful for shafts. Figure 2. Stair landing beam shaft wall structural penetration prior to fire caulk installation. 1-Hour Wall with Shaftliner 2-Hour Wall with Shaftliner • UL V455 • UL V433 • UL U336 • UL U373 • UL U375 ...Sound Tested with 2”x 4” stud wall with 1/2” (12.7 mm) ToughRock® Fireguard C wallboard or DensArmor Plus® Fireguard C panels and 3-1/2” (89 mm) fiberglass insulation in stud space. Breakaway clip facings and height of wall differ between UL Design U373 and WHI GP/WA 120-03. Consult each listing for specific information. Return to results :: Keyword: "UL U373" Gypsum Board. UL Certified. DOCUMENT: CKNX.R3501 · Product Code (UL CCN): CKNX The document listing is represented by a combination of the UL CCN and File Number. A UL CCN (Category Control Number) is the code that represents the Product Category (Category Description). See below for more …Title: UL Design No. U338 Author: Powers Created Date: 3/26/2007 3:17:35 PMApplications USG area separation wall systems are lightweight, non-load-bearing gypsum panel partition assemblies used to provide fire-resistive protection for common walls in townhouse construction. These systems install quickly and easily.Human U373 cells transfected with pCDNA3UL144 were fixed and permeabilized 48 h post-transfection and probed with FITC conjugated anti-T7 (green) and polyclonal anti-TRAF6 followed by anti-rabbit ...Các tem UL recognized thường dễ đạt được hơn UL listed. Điều này là do các nhà sản xuất có thể chọn các thành phần được chứng nhận trong một hệ thống lớn hơn. Việc công …Title: UL Design No. U338 Author: Powers Created Date: 3/26/2007 3:17:35 PM Note has been added to Detail 1-Common Wall & Detail 6-Common wall on sheet AD-7, referencing UL U373 & UL U336 non-bearing 2-HR area separation items 1,2,3. Depicted below is from manufacturer’s fire rated product installation requirements as approved by ANSI/UL 263. Detail 1-Common Wall & Detail 6-Common Wall follow the design ...Title: UL Design No. U338 Author: Powers Created Date: 3/26/2007 3:17:35 PM, Underwriters Laboratories (UL) Fire Resistance Directory, Intertek Testing Se rvices' Di-rectory of Listed Products, and the Gypsum Associa-tion's . Fire Resistance Design Manual (GA 600). The American Wood Council (AWC) and its members have tested a number of woodframe fire- -resistance-rated as-semblies (see photos). Descriptions of ...Oct 13, 2020 · USG MEXICO S A DE C V — Type DCB. 5. Batts and Blankets* — Placed to fill interior of stud cavity; 3 in. min thickness. THERMAFIBER INC — Type SAFB. 6. Gypsum Board* — Applied vertically 5/8 in. thick, attached to studs with 1 in. Type S-12 steel screws, spaced 8 in. Methods : The human glioma cell lines U87 MG (p53-wild type) and U373 MG (p53-mutant type) were irradiated in vitro via Gamma Knife 23004B2 using specially ...UL U356 Assembly as Defined, in Minutes UL U356 for a lis Exterior manufacturersSide Min SPF " Fire Rated Thermo-Ply® Red or Blue attached to studs then assembly siding types applied One-hour rated assembly fire endurance from interior side only See ting of of 5/ 8 GWB that can be applied to achieve a Finish Rating of 20.4 minutes or greater as8 thg 9, 2020 ... When the QR-500 or QR-510 panel is installed between the wood framing and the. UL Classified gypsum board, the required UL Classified gypsum ...BXUV.U347 - Fire-resistance Ratings - ANSI/UL 263 Author: jnye Created Date: 3/13/2017 4:07:02 PM ... 05-ST-F0851 – Issue 4.0 File : ULC-S100A CAN/ULC-S101 ULC G5.2 28 March 2019 STANDARDS BULLETIN 2019-18 REVISION TO STANDARD Revision 1 to Fifth Edition of CAN/ULC-S101-14-REV178. System Thickness. 16 3/32 in. CAD/Revit & Acoustics. Revit PDF. Visit UL L570 on the UL website. More. Assembly Construction.Fire Test Conducted in accordance with. ASTM E119. The passive fire resistance provided by fire-resistant rated gypsum based assemblies for walls, ceilings, floors, and other building systems, slows or prevents the spread of fire, allows time for evacuation, and limits fire damage. Passive fire protection measures are intended to contain a fire ...•Review typical UL 263 (ASTM E119) area separation wall Designs (U336, U347, U373) •Review the tested conditions and their relevance to field conditions •Review basic end/perimeter air sealing possibilities with respect to existing approved designs •Review possibilities for air sealing the entire protected wall (as if it were an ...We would like to show you a description here but the site won’t allow us.Title: UL Design No. U338 Author: Powers Created Date: 3/26/2007 3:17:35 PMGypsum Board* — (As an alternate to Item 2) — Any 5/8 in. thick UL Classified Gypsum Board that is eligible for use in Design Nos. L501, G512 or U305 — Nom. 5/8 in. thick gypsum board, paper or vinyl faced with beveled, square, tapered or rounded edges. Gypsum board nailed toEnvironmental Exposures (ANSI/UL 263, ASTM E119) 3. REFERENCED DOCUMENTS ANSI/UL 263, 14th Ed. (ASTM E119), Fire Tests of Building Construction and Materials ANSI/UL 723, 10th Ed. (ASTM E84), Test for Surface Burning Characteristics of Building MaterialsTranscription . Area Separation Walls (DensGlass® Shaftliner) - GeorgiaOct 13, 2020 · USG MEXICO S A DE C V — Type DCB. 5. Batts and Blankets* — Placed to fill interior of stud cavity; 3 in. min thickness. THERMAFIBER INC — Type SAFB. 6. Gypsum Board* — Applied vertically 5/8 in. thick, attached to studs with 1 in. Type S-12 steel screws, spaced 8 in. GRAPEVINE, TX The Gaylord Texan Resort And Convention Center. $120 million expansion broke ground Sept. 8, 2016 and was completed in the second quarter of 2018 . Approx 800,000 lbs of metal manufactured by Telling Industries. It was completed in 2018. The leader in metal framing innovation.Human U373 cells were transfected with pCDNA3 or pCDNA3UL144 as indicated and immunoprecipitated with an irrelevant isotypic antibody ( À ) or anti-T7 tag ( þ ) and analysed by SDS–PAGE and ...UL Design U373 Area Separation Wall assembly was evaluated at a height up to 44’ (13,411 mm) and the ITS/WHI GP/WA 120-04 Area Separation Wall assembly was evaluated at …Title: FIRE-RESISTANCE RATINGS - ANSI/UL 263 | UL Product iQ Author: ctallen Created Date: 5/7/2019 4:29:04 PMStandard UL 263 shall be permitted to be used to determine the hourly fire endurance rating of walls and floors with control joints. 1.11 Tests for determining the surface burning characteristics of building materials, based on the rate of flame spread, are found in the Standard for Test for Surface Burning Characteristics of Building Materials ...UL Design No. W454 (National Gypsum Co.) (2) Layers of 1” thick gypsum board liner panels fit into H-Studs w/ (1) layer of 5/8” thick gypsum board on each side of wall assembly. Standard 2-1/2” long Aluminum Breakaway Clips can be used to secure assembly. 3 Hour UL Listings: W454 (1-3/8” flange) 3 hour; W467 (1-3/8” flange) 3 hourArchitext Inc., providing font and bar code solutions for multiple platforms, including Windows, Macintosh, DOS, and UNIX. We also support multiple printers - HP ...TECHNICAL GUIDE SHAFTLINER FOR AREA SEPARATION WALLS DensGlass® Shaftliner Area Separation Walls For latest information and updates: Technical Service Hotline 18002256119…• UL U370 • GA WP 3820 Figure 3. Options for fire resistance rated, wood frame wall assemblies that could be useful for shafts. Figure 2. Stair landing beam shaft wall structural penetration prior to fire caulk installation. 1-Hour Wall with Shaftliner 2-Hour Wall with Shaftliner • UL V455 • UL V433 • UL U336 • UL U373 • UL U375 ...BXUV.U347 - Fire-resistance Ratings - ANSI/UL 263 Author: jnye Created Date: 3/13/2017 4:07:02 PM ...We would like to show you a description here but the site won’t allow us.BXUV.U347 - Fire-resistance Ratings - ANSI/UL 263. 3/4" AIR SPACE CONFIGURATION A EXPOSED TO FIRE FROM AREA SEPARATION WALL SIDE ONLY. 3/4" AIR SPACE CONFIGURATION D EXPOSED TO FIRE FROM EITHER SIDE Configuration C 3/4" AIR SPACE 3/4" AIR SPACE CONFIGURATION B EXPOSED TO FIRE FROM EITHER SIDE.. 2018 19 structural COMPONENTS Richard McLa– UL/ULC Classified for fire resistance (type SLX) – Panels are Revit, CAD, and construction details for fire rated wall assemblies can be downloaded for planning and material estimation. About Our Sustainability Commitment Blog Careers Contact Us Where to Buy. Tools & Documents Data Sheets Safety Data Sheets FAQs Technical Support. Connect with us. Tel: 317-398-4434 Fax: 317-398-3675 Sales: 800-825-4434 ... UL is committed to meeting our customers’ needs. Unde Sound Tested with 2”x 4” stud wall with 1/2” (12.7 mm) ToughRock® Fireguard C wallboard or DensArmor Plus® Fireguard C panels and 3-1/2” (89 mm) fiberglass insulation in stud space. Breakaway clip facings and height of wall differ between UL Design U373 and WHI GP/WA 120-03. Consult each listing for specific information. Fiberglass Insulation. The smart choice to make spaces more comfortable and energy efficient. R-Value. The ability to resist heat flow — insulation's thermal resistance. Thermal Properties. Ability to provide thermal resistance for comfort and efficiency. Insulating for Sound. Sound absorption characteristics, helping reduce noise transmission. Title: FIRE-RESISTANCE RATINGS - ANSI/UL ...

Continue Reading